Roman Piszcz

Live support:

Monday - Friday 6AM - 6PM PST

BJL26125LU Schneider Electric Industrial Automation Components

Schneider Electric BJL26125LU Square D by Schneider Electric BJL26125LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 125 TMD 2P design. It has a rated current of 125A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type includes Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the line side only. It offers a degree of protection of IP40 and is designed for mounting either fixed on DIN rail or as an individual unit mount on plate. This 2-pole (2P) circuit breaker has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. It is categorized under utilisation category A. The protection settings include over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. It features thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a mechanical durability of 20,000 operations at no load. The frame current rating is 125 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards, with a 50kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric

Part#:BJL26125LU

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric BJL26125LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 125 TMD 2P design. It has a rated current of 125A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type includes Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the line side only. It offers a degree of protection of IP40 and is designed for mounting either fixed on DIN rail or as an individual unit mount on plate. This 2-pole (2P) circuit breaker has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. It is categorized under utilisation category A. The protection settings include over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. It features thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a mechanical durability of 20,000 operations at no load. The frame current rating is 125 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards, with a 50kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at marketplace.quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BJL26125LU Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Breaking Capacity
    100 kA 208Y/120 V AC 50/60 Hz UL 489 100 kA 240 V AC 50/60 Hz UL 489 65 kA 480/277 V AC 50/60 Hz UL 489 65 kA 480 V AC 50/60 Hz UL 489 25 kA 600Y/347 V AC 50/60 Hz UL 489 50 kA 250 V DC UL 489
  • [Ics] Rated Service Breaking Capacity
    100 kA 220...240 V AC 50/60 Hz IEC 60947-2 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • Mounting Mode
    Clip-on 35 mm symmetrical DIN rail) By screws plate)
  • AWG Gauge
    AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
  • Electrical Connection
    Everlink lug line Everlink lug load
  • Depth
    3.15 in (80 mm)
  • Net Weight
    1.70 lb(US) (0.769 kg)
  • 9 Mm Pitches
    6
  • Width
    2.13 in (54 mm)
  • Quantity Per Set
    Set of 1
  • Height
    5.39 in (137 mm)
  • Color
    Grey (RAL 7016)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Connection Pitch
    1.06 in (27 mm)
  • Utilisation Category
    Category A
  • Mechanical Durability
    15000 cycles IEC 947-1 Annex K ed 5.2
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Trip Unit Name
    TM-D
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Trip Unit Technology
    Thermal-magnetic
  • Continuous Current Rating
    80 %
  • [Ue] Rated Operational Voltage
    690 V AC 50/60 Hz UL 489
  • Breaking Capacity Code
    J
  • Number Of Poles
    2P
  • Protected Poles Description
    2t
  • Product Name
    PowerPact B
  • Control Type
    Toggle
  • Line Rated Current
    125 A
  • Device Application
    Distribution
  • Product Or Component Type
    Circuit breaker
  • Range
    PowerPact
  • Device Short Name
    BJ 125

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

BJL26030LU Part Image. Manufactured by Schneider Electric.

BJL26030LU

Verified stock: 0

Square D by Schneider Electric BJL26030LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 30A 600Y/347Vac 25kA design. It includes Everlink (Creep compensating) lugs on both line and load sides and a Control Wire terminal (CWT) on the line side only. This MCCB has a rated impulse voltage (Uimp) of 8 kV, an IP40 degree of protection, and a rated current of 30A. It operates at a rated voltage (AC) of 600Vac 600Y/347Vac, with a mechanical durability of 20,000 operations when not under load. The BJL26030LU can be mounted on a DIN rail or individually mounted on a plate, features 2 poles (2P), and has dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A, with protection settings including over-current fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Its protection functions encompass thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 30 AT. The electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and the short circuit breaking rating includes 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL26035LU Part Image. Manufactured by Schneider Electric.

BJL26035LU

Verified stock: 0

Square D by Schneider Electric BJL26035LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 35A 600Y/347Vac 25kA design. It includes Everlink (Creep compensating) lugs on both line and load sides and a Control Wire terminal (CWT) on the line side only. This MCCB offers a degree of protection of IP40 and has a rated current of 35A with a rated voltage of 600Vac 600Y/347Vac. It is designed for fixed mounting on DIN rail or individual unit mount on a plate and has 2 poles (2P). The net dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and features over-current protection fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 35 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL26050LU Part Image. Manufactured by Schneider Electric.

BJL26050LU

Verified stock: 0

Square D by Schneider Electric BJL26050LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 50A 600Y/347Vac design with a rated impulse voltage of 8 kV. It includes Everlink (Creep compensating) lugs on both line and load sides and a Control Wire terminal (CWT) on the line side only, offering a degree of protection of IP40. This MCCB has a rated current of 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac, and provides mechanical durability of 20,000 operations when mounted either on a DIN rail or as an individual unit on a plate. It is a 2-pole (2P) device with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it features protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT and an electrical durability (with load) of 10,000 operations at 440Vac; In. The frame current rating is 100 AF, operated by a toggle (manual) mode, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo