LV433207
Schneider Electric LV433207 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range. This 4-pole MCCB features lug connection type and offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 80A and a rated insulation voltage (Ui) of 800V. The protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In), with a short-circuit pickup current fixed at 640A and a fully protected neutral pickup current of 1 times the rated current (Ir). The rated impulse voltage (Uimp) is 8kV, and the trip current rating is 80 AT, with a frame current rating of 100 AF. It boasts mechanical durability of 20,000 operations at no load and electrical durability of 10,000 operations at 690Vac with half the rated current (In/2) and 5,000 operations at 690Vac with the rated current (In). The rated voltage for phase-to-phase is 690V, and all four poles are protected. The trip unit type is TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV433205
Schneider Electric LV433205 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range. This 4-pole MCCB features lug connection type and offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 63A, with a rated insulation voltage (Ui) of 800 V. The protection settings include over-current adjustable from 0.7 - 1.0 x In, short-circuit pickup current fixed at 500A, and a fully protected neutral pickup current of 1 x Ir. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 63 AT and a frame current rating of 100 AF. It boasts mechanical durability of 20,000 operations at no load and electrical durability of 10,000 operations at 690Vac with half the rated current (In/2), and 5,000 operations at 690Vac with the rated current (In). The rated voltage for phase-to-phase is 690 V, and all four poles are protected. The trip unit type is TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV433203
Schneider Electric LV433203 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range. This 4-pole MCCB features lug connection type and offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 50A, with a rated insulation voltage (Ui) of 800 V. The protection settings include over-current adjustable from 0.7 - 1.0 x In, a short-circuit pickup current fixed at 500A, and a fully protected neutral pickup current of 1 x Ir. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 50 AT and a frame current rating of 100 AF. It boasts mechanical durability of 20,000 operations at no load and electrical durability of 10,000 operations at 690Vac with half the rated current (In/2), and 5,000 operations at 690Vac with the rated current (In). The rated voltage for phase-to-phase is 690 V, and all four poles are protected. The trip unit type is TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV433201
Schneider Electric LV433201 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed with a lug connection type and featuring 4 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this device is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In, a short-circuit pickup current fixed at 500A, and a fully protected neutral pickup current of 1 x Ir. It has a rated impulse voltage (Uimp) of 8 kV and a trip current rating of 40 AT. The frame current rating stands at 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability is specified as 10,000 operations at 690Vac with half the rated current (In/2) and 5,000 operations at 690Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690 V, with all 4 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under the utilisation category A.
Schneider Electric
Quick Quote
LV432895
Schneider Electric LV432895 is a Moulded Case Circuit Breaker (MCCB) within the NSX630H sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 630A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 6900A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 630 AT and a frame current rating of 630 AF. Mechanical durability is rated at 15,000 operations at no load, and electrical durability at 8,000 operations (440Vac; In/2) and 4,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and it protects 3 poles. The trip unit type is Micrologic 2.3 (LI) Interchangeable Electronic, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432876
Schneider Electric LV432876 is a Moulded Case Circuit Breaker (MCCB) within the NSX630F sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 630A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 6900A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 630 AT and a frame current rating of 630 AF. Mechanical durability is rated at 15,000 operations at no load, and electrical durability at 8,000 operations (440Vac; In/2) and 4,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. It features a Micrologic 2.3 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV432805
Schneider Electric LV432805 is a frame designed for use with NSX630L systems, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for 3 poles. The rated current for this frame is 630A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 630 AF. It boasts a mechanical durability of 15,000 operations at no load and an electrical durability of 8,000 operations at 440Vac with half the rated current (In/2), and 4,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it is designed to protect 3 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432804
Schneider Electric LV432804 is a frame designed for use with NSX630H (Frame) sub-range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for 3 poles. The rated current for this part is 630A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 630 AF. It boasts a mechanical durability of 15,000 operations at no load and an electrical durability of 8,000 operations at 440Vac with half the rated current (In/2), and 4,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it protects 3 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432677
Schneider Electric LV432677 is a Moulded Case Circuit Breaker (MCCB) within the NSX400F sub-range, designed for lug connection and featuring 4 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 400A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 4800A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 400 AT and a frame current rating of 400 AF. Mechanical durability is rated at 15,000 operations at no load, and electrical durability at 12,000 operations (440Vac; In/2) and 6,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. It features a Micrologic 2.3 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV432676
Schneider Electric LV432676 is a Moulded Case Circuit Breaker (MCCB) within the NSX400F sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 400A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 4800A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 400 AT and a frame current rating of 400 AF. Mechanical durability is rated at 15,000 operations at no load, and electrical durability at 12,000 operations (440Vac; In/2) and 6,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. It features a Micrologic 2.3 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV432413
Schneider Electric LV432413 is a frame designed for use within the NSX400F range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for 3 poles. The rated current for this part is 400A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 400 AF. It boasts a mechanical durability of 15,000 operations at no load and an electrical durability of 12,000 operations at 440Vac with half the rated current (In/2), and 6,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it protects 3 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432404
Schneider Electric LV432404 is a frame designed for use with NSX400H sub-range systems, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and supports 3 poles. The rated current for this part is 400A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 400 AF. It boasts a mechanical durability of 15,000 operations at no load and an electrical durability of 12,000 operations at 440Vac with half the rated current (In/2), and 6,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it protects 3 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432403
Schneider Electric LV432403 is a frame designed for use with NSX400N sub-range systems, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for three poles. The rated current for this part is 400A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 400 AF. It boasts a mechanical durability of 15,000 operations at no load and an electrical durability of 12,000 operations at 440Vac with half the rated current (In/2), and 6,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it is designed to protect three poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV432112
Schneider Electric LV432112 is a 4-pole trip unit designed for use in electrical protection and management systems. It belongs to the Micrologic 6.3E (LSIG) sub-range and serves as a standalone trip unit. This part is engineered to provide comprehensive protection functions including Long-time (L), Short-time with fixed time delay (S0), Instantaneous (I), and Ground fault (G) protection. It supports a rated current of 400A and offers adjustable protection settings: Long-time protection can be adjusted from 0.4 to 1 times the rated current (In), Short-time protection's adjustable time delay ranges from 1.5 to 15 times the rated current (Ir) with a time delay of 0.1 to 0.4 seconds, Instantaneous protection is adjustable from 1.5 to 12 times In, and Ground fault protection is adjustable from 0.2 to 1 times In with a time delay of 0.1 to 0.4 seconds. The trip current rating is specified at 400 AT, and all four poles are protected. This interchangeable electronic trip unit also features advanced measurement functions including current (I1, I2, I3, IN, Imax), ground fault percentage, voltage (U12, U23, U31, V1N, V2N, V3N, Uavg, Vavg), voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi, Energy in kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion for current and voltage (THDu, THDv, THDi).
Schneider Electric
Quick Quote
LV432109
Schneider Electric LV432109 is a trip unit designed for use in electrical protection systems. It belongs to the Micrologic 6.3E (LSIG) sub-range and functions as a trip unit alone. This model is equipped with three poles and offers a variety of protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), Instantaneous protection (I), and Ground fault protection (G). The rated current for this unit is 400A. Protection settings are adjustable, with Long-time protection ranging from 0.4 to 1 x In, Short-time protection and its time delay adjustable from 1.5 to 15 x Ir and from 0.1 to 0.4s respectively, Instantaneous protection adjustable from 1.5 to 12 x In, and Ground fault protection adjustable from 0.2 to 1 x In with a time delay of 0.1 to 0.4s. The trip current rating stands at 400 AT, and it protects three poles. The LV432109 features an interchangeable electronic trip unit type, Micrologic 6.3E (LSIG). It also includes measurement functions such as current and voltage in individual phases, maximum current, ground fault current percentage, unbalance percentage, voltage between phases and to neutral, average voltage, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy consumption (kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion for current and voltage (THDu, THDv, THDi).
Schneider Electric
Quick Quote
LV432108
Schneider Electric LV432108 is a trip unit designed for use in electrical protection systems. It belongs to the Micrologic 6.3E (LSIG) sub-range and functions solely as a trip unit. This model is equipped with three poles and offers a variety of protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), Instantaneous protection (I), and Ground fault protection (G). The rated current for this unit is 630A. Protection settings are adjustable, with Long-time protection ranging from 0.4 to 1 times the rated current (In), Short-time protection adjustable from 1.5 to 15 times the rated current (Ir) with a time delay between 0.1 to 0.4 seconds, Instantaneous protection adjustable from 1.5 to 15 times In, and Ground fault protection adjustable from 0.2 to 1 times In with a time delay of 0.1 to 0.4 seconds. The trip current rating stands at 630 AT, and it protects all three poles. The LV432108 features an interchangeable electronic Micrologic 6.3E (LSIG) trip unit type. Its measurement functions include current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy consumption (kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion for current and voltage (THDu, THDv, THDi).
Schneider Electric
Quick Quote
LV432106
Schneider Electric LV432106 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 6.3A (LSIG) sub-range and is characterized by its 4-pole configuration. This trip unit is equipped with multiple protection functions including Long-time (L), Short-time with fixed time delay (S0), Instantaneous (I), and Ground fault (G) protection. It has a rated current of 400A and offers adjustable protection settings: Long-time protection adjustable from 0.4 to 1 x In, Short-time protection with adjustable time delay from 1.5 to 15 x Ir and a time delay range from 0.1 to 0.4s, Instantaneous protection adjustable from 1.5 to 12 x In, and Ground fault protection adjustable from 0.2 to 1 x In with a time delay of 0.1 to 0.4s. The trip current rating is 400 AT, and it protects all 4 poles. This interchangeable electronic trip unit also features measurement functions for current (I1, I2, I3, IN, Imax) and ground imbalance (% unbalance%).
Schneider Electric
Quick Quote
LV432105
Schneider Electric LV432105 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 6.3A (LSIG) sub-range and is characterized by its 4 Pole configuration. This unit is equipped with multiple protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), Instantaneous protection (I), and Ground fault protection (G). It has a rated current of 630A and offers adjustable protection settings: Long-time protection adjustable from 0.4 to 1 x In, Short-time protection with adjustable time delay adjustable from 1.5 to 15 x Ir with a time delay range from 0.1 to 0.4 seconds, Instantaneous protection adjustable from 1.5 to 15 x In, and Ground fault protection adjustable from 0.2 to 1 x In with a time delay of 0.1 to 0.4 seconds. The trip current rating is 630 AT, and it protects all 4 poles. This trip unit is an interchangeable electronic type and includes measurement functions for I1, I2, I3, IN, Imax, Iground, and percentage unbalance.
Schneider Electric
Quick Quote
LV432103
Schneider Electric LV432103 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 6.3A (LSIG) sub-range and is characterized by its interchangeable electronic nature. This trip unit is specifically engineered for 3 Pole(s) configurations and offers a rated current of 400A. It features comprehensive protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection). The protection settings are adjustable, with long-time protection ranging from 0.4 to 1 x In, short-time protection and its time delay adjustable from 1.5 to 15 x Ir and 0.1 to 0.4s respectively, instantaneous protection from 1.5 to 12 x In, and ground fault protection from 0.2 to 1 x In with a time delay of 0.1 to 0.4s. The trip current rating stands at 400 AT, ensuring all 3 poles are protected. Additionally, it includes a measurement function for I1, I2, I3, IN, Imax, Iground, and percentage unbalance, enhancing its utility in monitoring and protection applications.
Schneider Electric
Quick Quote
LV432102
Schneider Electric LV432102 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 6.3A (LSIG) sub-range and functions solely as a trip unit. This model is equipped with three poles and offers a variety of protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), Instantaneous protection (I), and Ground fault protection (G). The rated current for this unit is 630A. Its protection settings are adjustable, with Long-time protection (L) ranging from 0.4 to 1 x In, Short-time protection (S) with an adjustable time delay ranging from 1.5 to 15 x Ir and a time delay from 0.1 to 0.4s, Instantaneous protection (I) adjustable from 1.5 to 15 x In, and Ground fault protection (G) adjustable from 0.2 to 1 x In with a time delay of 0.1 to 0.4s. The trip current rating stands at 630 AT, and it protects three poles. The LV432102 features an interchangeable electronic trip unit type, Micrologic 6.3A (LSIG), and includes measurement functions for I1, I2, I3, IN, Imax, Iground, and percentage unbalance.
Schneider Electric
Quick Quote